DRY_TE5 HP

EVAPORATOR “OUT” TE5 ERROR Cause Evaporator “OUT” Thermistor open or shorted. Solution Check the connectors. Check the Thermistors resistance, 10-12Kohm at room temperature. Check the PCB for 5Vdc. DETAILS BELOW: https://lgerrorcodes.com/wp-content/uploads/2024/03/TE5-Error-HP.mp4 The Evaporator Outlet Thermistor will be located in a holder on the copper tubing coming out of the evaporator coil. Examples below show where […]

DRY_LE2 HP

COMPRESSOR ERROR Cause   Compressor failure. Solution  Check compressor voltage and winding values, May require new compressor or Main PCB Compressor Ohm Values will vary based on the compressor type installed in the unit. Older heat pump dryers had reciprocating compressors while newer versions now use BLDC Compressors. Information on how to test both styles is […]

DRY_TE4 HP

EVAPORATOR “IN” TE4 ERROR Cause Evaporator “IN” Thermistor open or shorted. Solution Check the connectors. Check the Thermistors resistance, 10-12Kohm at room temperature. Check the PCB for 5Vdc. DETAILS BELOW: https://lgerrorcodes.com/wp-content/uploads/2024/03/TE4-Error-HP.mp4 The Evaporator Inlet thermister will be located in a holder on the copper tubing close to where the tubing enters the evaporator. The examples […]

DRY_TE3 HP

HEATER THERMISTOR TE3 ERROR Cause There is an issue with the Heater Thermistor. Solution Check the resistance of the thermistor. Replace the Harness, OR Replace the Main PCB,  DETAILS BELOW: The Heater Thermistor is mounted to the heater assembly located at the back of the unit. Remove all screws from the back cover to expose […]

DRY_LE3 HP

HEAT PUMP MODELS RESTRICTED FAN ERROR Cause The Dry Fan has tried to restart three times. Solution Check if the fan is restricted and can not move. Replace the DC Harness, OR Replace the Main PCB, OR Replace the Dry Fan DETAILS BELOW: The Dry Fan is part of the base assembly and is located […]

DRY_LE1 HP

HEAT PUMP DRYER TUB MOTOR IS LOCKED & CAN NOT TURN Cause For models that the tub motor also turns the blower motor. Defective Motor or no voltage to the motor.  Foreign item in the blower such as a dryer sheet Solution Check motor connection and motor winding resistance and voltage to the motor. Remove […]

FL_Turbidity Sensor

TURBIDITY SENSOR ERROR Cause Sensor Wiring Harness is Disconnected. PCB is Defective. Sensor is Defective. Solution Check the wiring for the sensor. Check the PCB for 5Vdc output. The Turbidity Sensor is monitoring the clarity of the water inside the unit. It is located at the bottom of the tub to the right of the […]

DRY_TE1 HP

Drum Outlet Thermistor Error Cause Temperature sensor failure or difference between actual and sensed temperature is significant. Solution Measure the resistance of the thermistor for proper values and if does not match for the temperature then replace the thermistor.  DETAILS BELOW: The Drum outlet sensor on the heat pump dryer, is located on the lower […]

DRY_TE2 HP

Compressor Discharge Pipe Thermistor Open/Short Cause   Compressor discharge (Outlet) temperature thermistor is shorted or open reading. Solution  Check thermistor for proper values. See the diagram below to check the COMPRESSOR THERMISTOR. This thermistor has been drawn in RED. https://lgerrorcodes.com/wp-content/uploads/2024/03/TE2-Error-HP.mp4 The number of pins in the wiring connectors can be different by model. Below are 2 […]

DRY_LE3

HEAT PUMP MODELS RESTRICTED FAN ERROR   Cause The Dry Fan has tried to restart three times.   Solution Check if the fan is restricted and can not move. Replace the DC Harness, OR Replace the Main PCB, OR Replace the Dry Fan   DETAILS BELOW: The Dry Fan is part of the base assembly […]