FL_LE3

DRYING BLOWER FAN MOTOR ERROR Cause The drying blower fan motor is restricted or locked. Solution If the connector for fan motor connection is disconnected, or it has a contact fault. Reconnect the connector and correct the poor connection. If the harness between the fan motor assembly and controller is open. Replace the fan-motor harness. […]
FL_1F

FILTER MISSING ERROR Cause An “IF” (IF) error code will display, and the machine will not start if the lint filter is left out of the machine. A magnet embedded in the lint filter activates the reed switch mounted internally in the plastic housing of the vent duct. Solution Check for lint filter installed and […]
FL_F1

TEMPERATURE TOO HIGH ERROR Cause The temperature in the tub is too high due to not enough air flow. Solution Remove the lint filter. Clean lint and rinse the filter then re-install. Clean the condenser, you can clean it with a brush and vacuum.
FL_tE5

EVAPORATOR OUTLET TEMPERATURE ERROR Cause Evaporator Outlet Thermistor Open, Short or detected when below -30 Cº or above 120 Cº Solution Check Evaporator Outlet Thermistor resistance and compare to the chart. The example below is from WM6998 There are 5 thermistors associated with the heat pump system
FL_tE4

EVAPORATOR INLET TEMPERATURE ERROR Cause Evaporator Inlet Thermistor Open, Short or detected when below -30 Cº or above 120 Cº Solution Check Evaporator Inlet Thermistor resistance and compare to the chart. The example below is from WM6998 There are 5 thermistors associated with the heat pump system
FL_tE3

DUCT OUTLET TEMPERATURE ERROR Cause Duct Outlet Thermistor Open, Short or detected when below -30 Cº or above 120 Cº Solution Check Duct Outlet Thermistor resistance and compare to the chart. The example below is from WM6998 There are 5 thermistors associated with the heat pump system
FL_tE2

COMPRESSOR INLET TEMPERATURE ERROR Cause Compressor Inlet Thermistor Open, Short or detected when below -20 Cº or above 200 Cº Solution Check Compressor Inlet Thermistor resistance and compare to the chart. The example below is from WM6998 There are 5 thermistors associated with the heat pump system
FL_tE1

DUCT INLET TEMPERATURE ERROR Cause Duct Inlet Thermistor Open, Short or detected when below -30 Cº or above 120 Cº Solution Check Duct Inlet Thermistor resistance and compare to the chart. The example below is from WM6998 There are 5 thermistors associated with the heat pump system
DRY_DE2

dE2 DOOR NOT LOCKED ERROR Cause Main board does not detect that the Door Lock switch is closed. Main board missing the 120VAC on the BLACK wire of the Door Lock Monitor Circuitry. Solution Make sure that the door is closed properly. Check for warped or misaligned door. Loose connection at the Main board or […]
DRY_DRN

DRAIN PUMP ERROR Cause Water level is not dropping after pump has ran. Solution Check drain hose was bent or folded. If folded, unfold the hose. If remaining water in drain hose is frozen, melt it with 140 °F (60°C) warm water If still Error displays, control valve may be damaged. Change the control valve […]