SK_UE

UNBALANCED ERROR CODE Cause The load is too small. Solution Add additional items to allow the washer to balance the load. Cause The motor IPM on the Main PCB sensed inconsistent current draw of the motor windings Solution Always try to wash articles of somewhat similar weight to allow the washer to evenly distribute the […]

SK_OE

OUTLET WATER ERROR CODE Cause Drain hose is kinked, pinched, or clogged. Solution Make sure that the drain hose is free of clogs or kinks and is not pinched behind or under the washer. DETAILS BELOW: 1.) Check for proper installation of the drain hose and that there are no obstructions in the drain hose. […]

SK_IE

INLET ERROR CODE Cause Water supply faucets are not fully open, or low water pressure. Water inlet hoses are kinked, pinched, or crushed. Solution Make sure that the water faucets are fully open. Make sure that the hoses are not kinked, pinched or crushed behind or under the washer. Be careful when moving the washer […]

SK_DE3

TUB LID OPEN ERROR Cause Main PCB has detected that Reed Switch 1 has opened. Reed Switch 1 is a normally open switch held closed by a magnet in normal operation. Solution Be sure to check that the tub lid is fully pushed down before closing the drawer. If still has an error then check […]

SK_DE2

DRAWER LOCK ERROR Cause Main PCB has not detected a 120Vac signal from door lock when attempting to lock drawer. Solution Check drawer alignment and lock and voltage to door lock. DETAILS BELOW: 1.) Is the drawer fully closing? 2.) Is the drawer warped or misaligned? 3.) Is the door lock installed correctly? 4.) Are the […]

SK_DE1

DRAWER OPEN ERROR Cause Main PCB not detecting that Reed Switch 2 is closing when the drawer is closed. Reed Switch 2 is a normally open(NO) switch. Solution Check drawer alignment and switch. DETAILS BELOW: 1.) Is the drawer closed? Is the drawer warped or misaligned? 2.) Unplug the unit. Check Reed Switch 2 for a […]

MW_F11

INVERTER COMMUNICATION ERROR Cause Communication error between Main PCB and Power PCB Solution Check the harness connection. DETAILS BELOW:

MW_F5

DAMPER SWITCH ERROR Cause Main PCB doesn’t see the Damper motor move when called for. The issue could be the Damper motor or the switch. Solution Check Damper motor connections and Switch connections. DETAILS BELOW:​

MW_F4

HUMIDITY SENSOR OPEN OR SHORTED Cause Shorted or Open thermistor is detected. Solution Check Main PCB connections and thermistor connections. DETAILS BELOW:

MW_F3

KEY PAD ERROR Cause When the error code F-3 shows but you can not use any button, the Main PCB doesn’t receive any touch signal. Solution Check the connections between the door harness and PCB assembly, reseat. You may need to replace keypad PCB. DETAILS BELOW: Touch Pad Issues No input. Some keys wont work. Random […]