FL_EE

EEPROM ERROR EEPROM stands for electrically erasable programmable read-only memory To test Enter test mode, At first press of the start button does the unit display the EE error code? Replace the main board
FL_BE

BALL SENSOR ERROR Cause The unit has experienced vibration at some point. Solution Visually check connections at Main Board and Stator (at Ball Sensor). Note* the ball sensor was only installed on models produced from approximately 2006 and earlier. DETAILS BELOW: Check if drum turns and will it spin? If it resumes a normal spin […]
FL_CE

OVER CURRENT ERROR Cause The Main Board has detected amperage of the stator is very high. Solution Visually check connections at Main Board and Stator. DETAILS BELOW: Does the drum spin freely by hand? If not inspect for object restricting movement of drum. Remove object if found. If no object found, replace bearings. If […]
FL_FF
FROZEN FAILURE Cause If FF is displayed on a Front Load washer, it means the unit is in a Frozen state. Solution Check the supply lines and drain hose, also check the drain filter to see if it is also frozen. Supply warm water into the tub in order to unfreeze the drain hose and […]
FL_TCL

TUB CLEAN CYCLE (NOT AN ERROR) Cause TCL isn’t an error code. This is an indicator that the Tub Clean cycle either is running or needs to run. On some models TC is displayed then the L is displayed. Solution TUB CLEAN cycle is specially designed to remove detergent residue build-up. (Detergent residue that builds […]
FL_CO1

WI-FI PROGRAM VERSION (NOT AN ERROR) There is no problem with the WI-FI module, this is a WI-FI program version. WI-FI version can change. This will only display in Test Mode.
FL_SUD

SUDS ERROR Cause If the washing machine detects too many suds, it displays this error code and adds Suds Reducing cycle. This adds about two hours to the cycle time.If too many suds are detected during spin, the washing machine stops to help prevent leaking. This washer is designed for use with only HE (High- […]
FL_DE2

dE2 DOOR NOT LOCKED ERROR Cause Main board does not detect that the Door Lock switch is closed. Main board missing the 120VAC on the BLACK wire of the Door Lock Monitor Circuitry. Solution Make sure that the door is closed properly. Check for warped or misaligned door. Loose connection at the Main board or […]
FL_DE1

dE1 DOOR OPEN ERROR Cause Main PCB does not detect that the interlock switch is closed.The Main PCB does not detect 120Vac on the Blue wire from the door lock when the door is closed. Solution Make sure that the door is closed properly. Check for warped or misaligned door. Loose connection at the Main […]
FL_FE

OVERFILL ERROR (FRONT LOAD WASHER) Cause Water level too high Solution The pressure sensor frequency has exceeded 213 and is detecting an overflow of water. DETAILS BELOW: Use test mode to check water level frequencyIs the water level frequency over 21.3kHz? (When adding water does your number decrease on display?)If no: does water flow continuously […]