SK_DE3

TUB LID OPEN ERROR Cause Main PCB has detected that Reed Switch 1 has opened. Reed Switch 1 is a normally open switch held closed by a magnet in normal operation. Solution Be sure to check that the tub lid is fully pushed down before closing the drawer. If still has an error then check […]

SK_DE2

DRAWER LOCK ERROR Cause Main PCB has not detected a 120Vac signal from door lock when attempting to lock drawer. Solution Check drawer alignment and lock and voltage to door lock. DETAILS BELOW: 1.) Is the drawer fully closing? 2.) Is the drawer warped or misaligned? 3.) Is the door lock installed correctly? 4.) Are the […]

SK_DE1

DRAWER OPEN ERROR Cause Main PCB not detecting that Reed Switch 2 is closing when the drawer is closed. Reed Switch 2 is a normally open(NO) switch. Solution Check drawer alignment and switch. DETAILS BELOW: 1.) Is the drawer closed? Is the drawer warped or misaligned? 2.) Unplug the unit. Check Reed Switch 2 for a […]