FL_PS

SUPPLIED VOLTAGE IS NOT CORRECT Cause Supplied voltage and rated voltage are not matched. Solution Check for proper voltage at the customer’s source. Voltage supplied to the unit should be 120Vac (+/-10%) If voltage at the wall is incorrect explain to customer. If voltage at the wall is correct, check at noise filter and Main […]
Combo HP Digital_CABINET SENSOR

CABINET SENSOR Cause There is an issue with the cabinet sensor, this can only be seen in LQC mode. Solution This error will not affect the operation of the unit. If you do see it and it is an issue, replace the Display PCB. DETAILS BELOW: Location of the Cabinet Sensor (The Cabinet Sensor […]
Combo HP Digital_DOOR UNLOCKED

DOOR UNLOCKED / DOOR OPENED Cause Check for objects around the door and door seal. Make sure the Door Gasket is properly installed. Solution Troubleshoot the Door Lock Assembly. DETAILS BELOW: Location of The Door Switch Operation of the Switch On this model the Main PCB is very difficult to access, so the best way […]
Combo HP Digital_UNBALANCE

UNBALANCE Cause If the washer attempts to enter the main speed cycle a UE is detected. The UE Error is detected only during the final spin. Solution Reload the laundry and try to restart the cycle. If it will not restart, then troubleshoot. The Load may be too small. The unit may be tilted. The […]
PET

P E T IS A NOTIFICATION Cause This is not an error code but a Notification that the cooktop is in a pet safe mode, which prevents pets from turning on and operating the product. Solution To turn this feature off press the LOCK key plus the TURBO key. This will also turn it on. […]
Combo HP Digital_NO WATER DETECTED

NO WATER DETECTED Cause In the event of a pressure sensor malfunction. If the pressure switch frequency remains below 10KHz or above 30KHz for 10 seconds. Solution Reload the laundry and try to restart the cycle. If it will not restart, then troubleshoot the Pressure Switch. DETAILS BELOW: 1.Check the Pressure Switch connections at the […]
Combo HP Digital_MOTOR ERROR

MOTOR ERROR Cause If the motor is locked 3 seconds after the motor starts, the LE Counter is started, if the LE Counter reaches 10 or more, a Motor error will occur. Solution Reload the laundry and try to restart the cycle. If it will not restart, then troubleshoot the motor circuit. DETAILS BELOW: Troubleshoot […]
Combo HP Digital_WATER TOO HIGH

WATER TOO HIGH Cause Water level too high. When the overflow water level of 21kHz or higher is continuously detected for 3 seconds. Note: In this case the drain pump will operate to drain the water automatically. Solution The pressure sensor frequency has exceeded 21.3kHz and is detecting an overflow of water. DETAILS BELOW: Check […]
Combo HP Digital_FREEZE ERROR

FREEZE ERROR Cause The unit has met any one or combination of four conditions. If the detected water temperature during operation is 14° Or lower for three consecutive times. In the instance of IE Error AND water temperature is between 15 ° and 26 ° (Except when the IE Error occurs after 25 minutes). 3. […]
Combo HP Digital_INVERTER PCB ERROR

INVERTER PCB ERROR Cause The Inverter PCB is not working properly. Solution Replace the Inverter PCB board. DETAILS BELOW: The Inverter PCB drives the Stator Tools needed… a stubby (short) Phillips Screwdriver, or a Ratcheting Right Angle Multi-Bit Screwdriver. Cut resistant gloves. Location The Inverter PCB is in the bottom at the rear of the […]