TL_DIGITAL DIAL_EZDISPENSE ERROR

EZDISPENSE ERROR Cause There is a communication issue between the Main PCB and the ezDispense™ Sub PCB. Solution Check wiring connections between the Main PCB and the ezDispense™ Sub PCB. Cause The ezDispense™ PCB is defective. Solution Replace the ezDispense™ PCB. https://youtu.be/kUQXSNxnOKw Start by simply making sure all harnesses are plugged into the ezDispense™ Sub […]

TL_DIGITAL DIAL_NO SOFTENER

NO SOFTENER Cause The ezDispenser™ PCB does not sense softener in the softener tank of the dispenser assembly. Solution Check the level of the softener to confirm, if there is no softener in the tank, refill it. If there is softener in the tank, try to clean it and the pump attachment on the softener […]

TL_DIGITAL DIAL_NO DETERGENT

NO DETERGENT Cause The ezDispenser™ PCB does not sense detergent in the detergent tank of the dispenser assembly. Solution Check the level of the detergent to confirm, if there is no detergent in the tank, refill it. If there is detergent in the tank, try to clean it and the pump attachment on the detergent […]

TL_DIGITAL DIAL_EZDISPENSE OPEN

ezDISPENSE DRAWER IS OPEN Cause **This is a courtesy message to inform the customer that the dispenser drawer is not closed properly.** The Dispenser Drawer closed switch is not activated. Solution Open the Dispenser Drawer and reinstall. Cause The Dispenser Drawer switch is defective. Solution Check the Dispenser Drawer Switch for continuity.  https://youtu.be/GbfxRmxNX2Q Step 1: […]

TL_DIGITAL DIAL_CHECK SOFTENER TANK

CHECK SOFTENER TANK Cause The amount of liquid in the Softener tank did not decrease (did not dispense detergent). Solution After putting Softener into the tank, it was left for a long time and the Softener hardened. The end user leaving the softener in the tank a long time may have caused a build-up of […]

TL_DIGITAL DIAL_CHECK DETERGENT TANK

CHECK DETERGENT TANK Cause The amount of liquid in the detergent tank did not decrease (did not dispense detergent). Solution After putting detergent into the tank, it was left for a long time and the detergent hardened. The End user leaving the detergent in the drawer a long time may cause a build-up of residue […]

REF_IH

FREEZER ICEMAKER SENSOR ERROR (CUBED ICEMAKER) Cause The Main PCB is not getting a signal from the Freezer Icemaker Sensor. Solution Check the wiring at the sensor under the left side hinge cover, and Main PCB. Remember an ERROR CODE will only appear if –  0 or 5Vdc is detected at the Main PCB DETAILS […]

REF_IE

FREEZER ICEMAKER ERROR (CUBED ICEMAKER) Cause Ice maker in freezer is defective or has no voltage to the ice maker Solution Check wiring and connections to freezer ice maker. Check voltage to the ice maker.  Cause Ice maker may be jammed with ice chips. Solution Thaw the ice maker and test again. Cause Heated mold […]

REF_SC

RGB SUB PCB COMMUNICATION ERROR Cause Communication error between Display PCB Micom and RGB Sub PCB Micom. Solution Check the wiring at RGB Sub PCB and the Display PCB. Check voltages between RGB Sub PCB and the Display PCB. DETAILS BELOW: Some LG Refrigerators have a feature called “MyColor™”… MyColor™ lets you change the InstaView® […]

under construction