DISH_F37

AUTO OPEN DRY MOTOR ERROR Cause Auto Open Dry motor error code Solution Check motor function in test mode. Check for 15Vdc on Black to Brown wires at the motor when Lever is programed to be opened. Please check the Lgtestmodes.com website for your specific model test mode. https://youtu.be/lGStRHGLAvo?si=Lq87kChv1fpK_Jhk DETAILS BELOW: The Auto Open Dry […]
REF_Cycle Error
CYCLE ERROR Cause A Cycle Error occurs in LQC mode if the Defrost Sensor temperature does not drop below 3.5°C (38.3°F) within 10 minutes after the LQC test begins Solution Check the Defrost sensor. Check the frost pattern. DETAILS BELOW: Frost Pattern: A weak frost pattern will indicate a Sealed System issue, which will also […]
REF_OD #2

WI-FI MODULE ERROR Cause Wi-Fi module failure, Main (or Display) PCB failure, or connector loose, or wiring issue. Solution Check all connections at door hinge, Main or Display PCB and at the WI-FI Module. Usually this requires a new WI-FI Module to repair. Note: Check your individual models Circuit Diagram and location of PCB’s For […]
R&O_CF9

Flex Top Sensor Failure Cause Open or Shorted Left CTS Top Thermistor Solution 1.Check the Top Sensor connection. (Open) 2.Check The Top Sensor Resistance. (Short) DETAILS BELOW: Check the connector CN11T, make sure, it is connected properly. The “Top Sensor for Single Burner” as pictured below is the sensor located in the center of the […]
FL_bU

HEAVY VIBRATION ERROR Cause Damaged drum welds. Solution Visually check the inner drum for broken/damaged welds. If welds are damaged replace drum assembly and any other needed parts that might have been damaged as a result. Cause Vibration sensor not mounted to tub properly. Solution Install vibration sensor properly. Cause Unit not leveled correctly. Solution […]
Compressorblinkcodes-BLDC
BLDC Compressor / Main PCB Blink Codes Definition: FCT0 Trip (Voltage) Trip Logic: Abnormal IPM sensing voltage. Reaction: Main PCB will apply power to the compressor after 30 seconds. Purpose: Main PCB circuit protection. Most Likely Cause: Main PCB Failure. Definition: Over Voltage Trip Trip Logic: Detection of over voltage to the Main PCB DC […]
Compressorblinkcodes-linear
Linear Compressor / Main PCB Blink Codes Definition: FCT0 Trip (Voltage) Trip Logic: Abnormal IPM sensing voltage. Reaction: Main PCB will apply power to the compressor after 30 seconds Purpose: Main PCB circuit protection. Most Likely Cause: Main PCB Failure. Definition: Stroke Trip Trip Logic: Main PCB detects the compressor piston over stroke. Reaction: Compressor […]
SelectCompressorType-blinkcodes
SELECT COMPRESSOR TYPE Blink Code meaning can vary based on the type of compressor that is installed in the unit. Please select Linear or BLDC below for the most accurate diagnosis information… To download a PDF containing both Linear and BLDC Blink Codes, Click Here: Blink Code PDF Download
DRY_E3

NO WATER SUPPLY (FOR STEAM) – Detects when the temperature of the Steam Thermistor is less than 8℃ (46.4F) from the previous 3 seconds for 60 seconds. Potential Causes: Inlet Hose Blockage: The inlet hose may be obstructed by foreign matter. Faulty Inlet Valve: A malfunctioning inlet valve can prevent water from entering the steam […]
TL_DIGITAL DIAL_DETERGENT AND SOFTENER ARE LOW
DETERGENT AND SOFTENER ARE LOW Cause **This is a courtesy message to inform the customer that they need to add detergent, softener, or both.** If the message is displaying and the detergent and softener compartments are full then there is likely an issue with the sensor that detects the level of detergent/softener. Solution Test the […]