WAC_93

COMMUNICATION ERROR Definition: Communication issue between the Main PCB and Display PCB. Cause Supply Voltage Issue. Solution Make sure the supply voltage to the unit is within correct range. Check the spec sheet to see if the unit is 115V/208V/230V and that the actual supplied voltage +/- 10% of the rated voltage required. Cause Wiring […]
WAC_60

EEPROM ERROR Cause Supply Voltage Issue. Solution Make sure the supply voltage to the unit is within correct range. Check the spec sheet to see if the unit is 115V/208V/230V and that the actual supplied voltage +/- 10% of the rated voltage required. ***If supply voltage is correct… Disconnect power for a few minutes to […]
WAC_EA

COMMUNICATION ERROR Definition: Communication issue between the Main PCB and Display PCB. Cause Supply Voltage Issue. Solution Make sure the supply voltage to the unit is within correct range. Check the spec sheet to see if the unit is 115V/208V/230V and that the actual supplied voltage +/- 10% of the rated voltage required. Cause Wiring […]
WAC_53

COMMUNICATION ERROR Definition: Communication issue between the Main PCB and Display PCB. Cause Supply Voltage Issue. Solution Make sure the supply voltage to the unit is within correct range. Check the spec sheet to see if the unit is 115V/208V/230V and that the actual supplied voltage +/- 10% of the rated voltage required. Cause Wiring […]
WAC_E3

REFRIGERANT LEAK ERROR Cause (If code is intermittent or unit is cooling correctly): Main PCB or Temperature Sensor defect. Solution Try Reset. If Reset does not work replace Main PCB and Temp Sensor(s). Cause Sealed System Leak. Solution Look for leaking sealed system component. Look for oil on tubing. Replace leaking part and repair sealed […]
WAC_38

REFRIGERANT LEAKAGE DETECTION Cause (If code is intermittent or unit is cooling correctly): Main PCB or Temperature Sensor defect. Solution Try Reset. If Reset does not work replace Main PCB and Temp Sensor(s). Cause Sealed System Leak. Solution Look for leaking sealed system component. Look for oil on tubing. Replace leaking part and repair sealed […]
WAC_36

REFRIGERANT LEAKAGE DETECTION Cause (If code is intermittent or unit is cooling correctly): Main PCB or Temperature Sensor defect. Solution Try Reset. If Reset does not work replace Main PCB and Temp Sensor(s). Cause Sealed System Leak. Solution Look for leaking sealed system component. Look for oil on tubing. Replace leaking part and repair sealed […]
WAC_43

HIGH PRESSURE SWITCH ERROR Cause Unit overheating / Restricted Airflow. Solution Check for fan obstruction causing reduced airflow. Check for dirty condenser coil. Check for proper installation. Cause Faulty Pressure Switch Solution Ohm test Pressure Switch to make sure it is closed. DETAILS BELOW:
WAC_34

HIGH PRESSURE SWITCH ERROR Cause Unit overheating / Restricted Airflow. Solution Check for fan obstruction causing reduced airflow. Check for dirty condenser coil. Check for proper installation. Cause Faulty Pressure Switch Solution Ohm test Pressure Switch to make sure it is closed. DETAILS BELOW:
WAC_24

HIGH PRESSURE SWITCH ERROR Cause Unit overheating / Restricted Airflow. Solution Check for fan obstruction causing reduced airflow. Check for dirty condenser coil. Check for proper installation. Cause Faulty Pressure Switch Solution Ohm test Pressure Switch to make sure it is closed. DETAILS BELOW: