CTP_2

TWO FLASH ERROR Cause Indicates an issue with TH2 is open/short or 35, 56 port of Micom (U21) is open/ short. Solution Turn the cooktop off using the Power ON / OFF. Turn the cooktop on using the ON / OFF. If the error persist continue to troubleshooting DETAILS BELOW:
CTP_1

ONE FLASH ERROR Cause Indicates an issue with a thermistor, or the Micom on the PCB. Solution Turn the cooktop off using the Power ON / OFF. Turn the cooktop on using the ON / OFF. If the error persist continue to troubleshooting. DETAILS BELOW:
DISH_HE

HEATER ERROR CODE Cause The water is not heated or the temperature in the tub is overheated to over 194º F Solution 1) Check wire connection. 2) Check the water temperature. If the temperature is less than 120º F the customer will need to adjust hot water temperature supplied to the unit. 3) Check the electric […]
WAC_P2

WATER TANK FULL (Portable AC) Cause Water Tank is full of water. Solution Manually empty water tank. Cause Float Switch Defect Solution If there is no water in the tank and the code is displaying the float switch circuit needs to be tested Check for breaks in harness between Main PCB and Float Switch. Check […]
WAC_FL

WATER TANK FULL (Portable AC) Cause Water Tank is full of water. Solution Manually empty water tank. Cause Float Switch Defect Solution If there is no water in the tank and the code is displaying the float switch circuit needs to be tested Check for breaks in harness between Main PCB and Float Switch. Check […]
WAC_E5

WATER TANK FULL (Portable AC) Cause Water Tank is full of water. Solution Manually empty water tank. Cause Float Switch Defect Solution If there is no water in the tank and the code is displaying the float switch circuit needs to be tested Check for breaks in harness between Main PCB and Float Switch. Check […]
WAC_E4

DEFROST MODE Cause The E4 Error is not actually an error code but indicates that the air conditioner has entered defrost mode. This happens when the pipe thermistor located on the evaporator coils senses that the coil temperature is at or below 35.6 degrees ºF. When the coil temperature reaches 46.4 ºF or higher the unit […]
WAC_E2

ROOM AIR TEMPERATURE SENSOR ERROR Cause Open /Shorted Sensor. Solution Check ohm reading of sensor. Cause Sensor disconnect. Solution Check for connection of sensor to Main PCB. Cause Sensor harness damage. Solution Inspect the sensor harness for damage/breaks. Check for moisture around connector. DETAILS BELOW:
WAC_E1

PIPE TEMPERATURE SENSOR ERROR Cause Open /Shorted Sensor. Solution Check ohm reading of sensor. Cause Sensor disconnect. Solution Check for connection of sensor to Main PCB Cause Sensor harness damage. Solution Inspect the sensor harness for damage/breaks. Check for moisture around connector. DETAILS BELOW:
WAC_67

BLDC FAN MOTOR ERROR Cause Fan Motor is physically stuck. Solution See if fan will turn by hand. If not check for obstructions around fan causing it to not turn. Cause Defective Fan Motor or Main PCB. Solution Test fan circuit. If voltage is present at fan and it will not turn Replace Fan motor. […]