kimchi_d1

Upper Compartment Defrost Sensor Malfunction Cause If d1 is displayed The Main board has stopped receiving a feedback signal from the Upper Defrost sensor. Solution Check The connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW:
kimchi_LS

Lower Compartment Sensor Malfunction Cause If LS is displayed The Main board has stopped receiving a feedback signal from the Lower Compartment Sensor. Solution Check The connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW:
kimchi_US

Middle Compartment Sensor Malfunction Cause If US is displayed The Main board has stopped receiving a feedback signal from the Middle Compartment Sensor. Solution Check The connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW:
kimchi_FS

Upper Compartment Sensor Malfunction Cause If FS is displayed The Main board has stopped receiving a feedback signal from the Upper compartment sensor. Solution Check The connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW:
Compressorblinkcodes
Compressor / Main PCB Blink Codes Cause: Main PCB Compressor voltage errors. What to check: Check compressor voltage from Main PCB and if not correct then replace the Main PCB. Cause: PCB Parts defect or Compressor connection (Piston over run). What to Check: Check compressor wire harness for a tight connection. If connection is good […]
DRY_E4

STEAM HEATING Error occurs when 221F (105℃) is not reached within 80 seconds during steam heating. 1. Check the wire connection of the Steam generator. 2.Replace Steam Generator.
DRY_E1

STEAM MODULE OVERHEATING When the water temperature of steam rises above 320F (160℃) the error occurs Replace Steam Generator.
TL_EE

EEPROM ERROR EEPROM stands for electrically erasable programmable read-only memory To test Enter test mode, At first press of the start button does the unit display the EE error code? Replace the main board
REF_IO

MINI CUBED ICE MAKER TEMPERATURE SENSOR Cause The Main PCB is not getting a signal from the Mini cubed Ice Maker sensor. Solution Check the wiring at the sensor connection and PCB. Check the sensor resistance and voltage Remember an ERROR CODE will only appear if 0 or 5Vdc is detected at the Main PCB DETAILS […]
REF_IC

IC MINI CUBED ICEMAKER MOTOR ERROR Cause Loose connection or mini cubed icemaker motor is defective or mini cubed icemaker motor does not receive 12Vdc. Solution Check wiring and connections to mini cubed ice maker. Check voltage to the mini cubed ice maker motor DETAILS BELOW: