SEALED SYSTEM LOW SIDE LEAK ERROR

Cause

Low side refrigerant leak (Evaporator), possible bad compressor, customer may have had the door open for a long time…etc.

Solution

Troubleshooting and inspection must be done to find the root cause of this error code.

DETAILS BELOW:

How to Clear the Error Code if Needed:

Below are the direct instructions from the factory.

The code should go away on its own after 24 hours of the unit reaching 14 degrees F or below after the unit is successfully repaired. If it does not go away after 24 hours and the temperature is staying below 14 degrees you can force it off by pressing Freezer and Refrigerator buttons at the same time 3 Times with the fridge door open…..

※ Freezer temperature is 14℉↓(After a day of SVC), the error code(E CH, E CL) disappears.
But, If temperature(sealed system) is normal and Error CH or CL displays continuously,
please press error forced deletion button.

※Error(CH or CL) forced deletion button(*Customer complaint rise and algorithm problem etc.)
F key + R key(3times) with the door open

20 Responses

    1. Below are the direct instructions from the factory.

      The code should go away on its own after 24 hours of the unit reaching 14 degrees F or below. If it does not go away after 24 hours and the temperature is staying below 14 degrees you can force it off by pressing Freezer and Refrigerator buttons at the same time 3 Times with the fridge door open…..

      ※ Freezer temperature is 14℉↓(After a day of SVC), the error code(E CH, E CL) disappears.
      But, If temperature(sealed system) is normal and Error CH or CL displays continuously,
      please press error forced deletion button.

      ※Error(CH or CL) forced deletion button(*Customer complaint rise and algorithm problem etc.)
      F key + R key(3times) with the door open

  1. RNN231205056797
    Customer move unit Found unit room temperature low 45psi high 75psi equalized 55psi replace compressor

  2. CL error code nor going away… tried the F&R three times with the door open and it’s still there. Tried updating the PCB and it’s still there….

    1. The code should go away on its own after 24 hours of the unit reaching 14 degrees F or below after the unit is successfully repaired.

  3. E CL error , In Cambodia found root cause from too much dusty at condenser .
    To solve this error just unplug power and make big cleaning on condenser after that the refrigerator will operation normal.