Cause
Low side refrigerant leak (Evaporator), possible bad compressor, customer may have had the door open for a long time…etc.
Solution
Troubleshooting and inspection must be done to find the root cause of this error code.
How to Clear the Error Code if Needed:
Below are the direct instructions from the factory.
The code should go away on its own after 24 hours of the unit reaching 14 degrees F or below after the unit is successfully repaired. If it does not go away after 24 hours and the temperature is staying below 14 degrees you can force it off by pressing Freezer and Refrigerator buttons at the same time 3 Times with the fridge door open…..
※ Freezer temperature is 14℉↓(After a day of SVC), the error code(E CH, E CL) disappears.
But, If temperature(sealed system) is normal and Error CH or CL displays continuously,
please press error forced deletion button.
※Error(CH or CL) forced deletion button(*Customer complaint rise and algorithm problem etc.)
F key + R key(3times) with the door open
17 Responses
How do you clear the error code?
Below are the direct instructions from the factory.
The code should go away on its own after 24 hours of the unit reaching 14 degrees F or below. If it does not go away after 24 hours and the temperature is staying below 14 degrees you can force it off by pressing Freezer and Refrigerator buttons at the same time 3 Times with the fridge door open…..
※ Freezer temperature is 14℉↓(After a day of SVC), the error code(E CH, E CL) disappears.
But, If temperature(sealed system) is normal and Error CH or CL displays continuously,
please press error forced deletion button.
※Error(CH or CL) forced deletion button(*Customer complaint rise and algorithm problem etc.)
F key + R key(3times) with the door open
RNN230817013838
RNN230921093150
RNN230923000602.
if its an R600 unit, and there is a leak, is the leak flammable?
RNN230927020270
RNN231027073239
CL E error code replaced compressor had FLE and updated board
RNN231104008342
CL error FLE compressor replaced compressor
RNN231110039513 AI103834
RNN231203043111
RNN231205056797
Customer move unit Found unit room temperature low 45psi high 75psi equalized 55psi replace compressor
RNN231205056839
CL error code Found condenser fan not worked replace it
RNN231209078269
RNN231230070596
GMX844BSBF
CL E error code replaced compressor had FLE and sw-updated board
Condenser motor replace and compressor replace but not resolved cl error