TL_OE

OUTLET WATER ERROR (Top Load Washer) Cause Drain hose is kinked, pinched, or clogged. Solution Make sure that the drain hose is free of clogs or kinks and is not pinched behind or under the washer. Cause The end of the drain hose is more than 96 inches above the bottom of the washer. Solution Move […]
TL_IE

INLET ERROR The Main PCB does not detect that any (or not enough) water has flowed into the tub based off the pressure sensor frequency. Cause Water supply faucets are not fully open, or low water pressure. Water inlet hoses are kinked, pinched, or crushed. Solution Make sure that the water faucets are fully open. […]
TL_UB

UNBALANCED ERROR Cause The unit is not properly leveled. Solution Level the unit making sure the drum is centered properly. Cause The load is too small. Solution Add additional items to allow the washer to balance the load. Cause Heavy articles are mixed with lighter items. Solution Always try to wash articles of somewhat similar […]
TL_UE

UNBALANCED ERROR CODE Cause The unit is not properly leveled. Solution Level the unit making sure the drum is centered properly. Cause The load is too small. Solution Add additional items to allow the washer to balance the load. Cause Heavy articles are mixed with lighter items. Solution Always try to wash articles of somewhat […]
TL_LE

LOCKED ROTOR ERROR Cause The motor can not turn Solution Check for tub moving freely by hand and if does not may it be a bad clutch assembly. Check for a foreign item between the tubs. If it does move freely check for cracked magnets on the rotor. The stator windings may have resistance values […]
REF_IF

ICING FAN ERROR Cause The Main PCB has stopped receiving a feedback signal from the Ice Fan. Solution Check the fan for movement, (if fan won’t move without power applied replace fan) or other issues that might stall fan. Check the fan for ice. Test Voltages in Test Mode 1 DETAILS BELOW: Special Note: For […]
TL_TE

TEMPERATURE SENSOR ERROR Cause Temperature Sensor Error Solution Check connections at theremistor and main board. Also check thermistor for proper resistance. DETAILS BELOW: Is connector to thermistor disconnected or corroded?With power on, does tE error still display when shaking thermistor connection?If so, reconnect or repair connector. The Main board should be outputting 5 VDC […]
REF_CF

CONDENSER FAN ERROR CauseThe Main board has stopped receiving a feedback signal from the Condenser Fan. SolutionCheck The fan for movement, (if fan won’t move without power applied replace fan) or other issues that might stall fan.Check the fan shroud for mis-alignment.Test Voltages in Test Mode 1 DETAILS BELOW:
REF_RF

REFRIGERATOR (FRESH FOOD) FAN ERROR Cause The Main board has stopped receiving a feedback signal from the Fresh Food Fan. Solution Check The fan for movement, (if fan won’t move without power applied replace fan) or other issues that might stall fan. DETAILS BELOW: Special Note: For Serial Range 109KR-309KR if the refrigerator fan is […]
REF_FF

FREEZER FAN ERROR Cause The Main board has stopped receiving a feedback signal from the Freezer Fan. Solution Check the fan area for heavy ice stopping the fan blade, or other issues that might stall fan. (the issue could be a Defrost issue instead of a fan issue). DETAILS BELOW: Special Note: […]