CONDENSER FAN ERROR

Cause
The Main board has stopped receiving a feedback signal from the Condenser Fan.

Solution
Check The fan for movement, (if fan won’t move without power applied replace fan) or other issues that might stall fan.
Check the fan shroud for mis-alignment.
Test Voltages in Test Mode 1

DETAILS BELOW:

50 Responses

  1. Submitted to be cancelled as unit was already repaired. I don’t want to get hit for not using this site.

    RNN231004053479

  2. RNN231107016961
    #Se # Not a sealed system issues. Customer concern about CF error code. Replaced bad condenser fan test unit works perfectly

  3. Not cooling properly. CF E displayed on the panel. Condenser fan not working. Replace condenser fan. All tested ok. No leaks after test. Customer instruct 24 hrs for going to the correct temperatures. RNN231111041552

  4. RNN231127009425

    Dispenser not working, CF error.
    Condenser fan jammed up due to crooked fan shroud, part readjusted, tested fine.

Leave a Reply

Your email address will not be published. Required fields are marked *