REF_ID

IN-FREEZER ICE MAKER ICING SENSOR ERROR Cause The Main PCB is not getting a signal from the Freezer Icing sensor. Solution Check the wiring at the sensor, and Main PCB. Remember an ERROR CODE will only appear if – 0 or 5Vdc is detected at the Main PCB DETAILS BELOW:
REF_IS

IN-DOOR ICE MAKER ICING SENSOR ERROR Cause The Main PCB is not getting a signal from the In-Door Icing sensor. Solution Check the wiring at the sensor under the left side hinge cover, and Main PCB. Remember an ERROR CODE will only appear if – 0 or 5Vdc is detected at the Main PCB DETAILS […]
TL_LE1

FOREIGN OBJECT ERROR Cause Foreign objects such as coins, pins, clips, are caught between pulsator and inner tub. Solution Turn the washer off then on again. Press the Spin button without selecting a cycle to drain and spin the load. When the Spin cycle is completed, empty the tub and find and remove any […]
REF_RS

REFRIGERATOR (FRESH FOOD) SENSOR ERROR Cause If rS is displayed The Main PCB is not getting a signal from the sensor. Solution Check the wiring at the sensor and Main PCB. Check thermistor for proper values. Remember an ERROR CODE will only appear if – 0 or 5Vdc is detected at the Main PCB DETAILS […]
TL_PS

POWER SUPPLY VOLTAGE ERROR (Top Load Washer) Cause The supply voltage is not correct. Solution If unit wont power up, check the power source, the unit will need 120Vac (+/- 5%), and correct polarity. DETAILS BELOW: After you have verified power supply from outlet, make sure you have 120Vac into and out of Filter board, […]
TL_E6

CLUTCH MOTOR ERROR Cause The Main PCB is not detecting the correct signal voltage from the clutch motor when engaging or disengaging the clutch. Solution If a clicking or grinding noise is made, disassemble the pulsator and tub to check for any foreign objects (coins, keys, hair pins, etc). If a foreign object is found, […]
REF_FS

FREEZER SENSOR ERROR Cause If FS is displayed The Main PCB is not getting a signal from the sensor. Solution Check the wiring at the sensor and Main PCB. Remember an ERROR CODE will only appear if 0 or 5Vdc is detected at the Main PCB DETAILS BELOW:
TL_PE

PRESSURE SWITCH ERROR (Top Load Washer) Cause Water Pressure Sensor isn’t working properly. Solution Make sure that the Pressure Sensor, connections are good at sensor, and main board. Check for oversudsing issues, if unit is in this condition, advise to run tub clean with a cleanser, such as, Affresh® Cause Small hole in pressure sensor […]
REF_CO

COMMUNICATION ERROR Cause If CO is displayed The Main board and Display have stopped communicating with each other. Solution Check the wiring at the left-hand hinge connections & the associated voltages. DETAILS BELOW: Continuity Test: Set meter to continuity and check the Rx/Tx lines from the Main PCB to the Left Door Hinge connector, […]
TL_FE

OVERFILL ERROR Cause Water level too high Solution Make sure that the water valve isn’t stuck. Be sure the customer is not using too much detergent causing an excess of suds and foam. The detergent should be High Efficiency detergent to reduce the possibility of over sudsing issues that interfere with the pressure sensor reading. […]