TEMPERATURE SENSOR ERROR

Cause

Temperature Sensor Error

 

Solution

Check connections at theremistor and main board.

Also check thermistor for proper resistance.

DETAILS BELOW:

Is connector to thermistor disconnected or corroded?
With power on, does tE error still display when shaking thermistor connection?
If so, reconnect or repair connector.

The Main board should be outputting 5 VDC to the thermistor wires measured with thermistor disconnected, if not replace main board, if yes, check thermistor resistance. 

2 Responses

  1. RNN231027070458
    Not completing cycles, tE error. Thermistor out of range, read only 11 ohms, needs between 80-90 ohms at room temp. Also Wireharness to thermistor is soft at the joint. Parts replaced; 6322FR2046G-(THERMISTOR ASSEMBLY), EAD62708424-(Harness,Multi), tested fine