TEMPERATURE SENSOR ERROR

Cause

Temperature Sensor Error

 

Solution

Check connections at theremistor and main board.

Also check thermistor for proper resistance.

DETAILS BELOW:

Is connector to thermistor disconnected or corroded?
With power on, does tE error still display when shaking thermistor connection?
If so, reconnect or repair connector.

The Main board should be outputting 5 VDC to the thermistor wires measured with thermistor disconnected, if not replace main board, if yes, check thermistor resistance. 

One Response

  1. RNN231027070458
    Not completing cycles, tE error. Thermistor out of range, read only 11 ohms, needs between 80-90 ohms at room temp. Also Wireharness to thermistor is soft at the joint. Parts replaced; 6322FR2046G-(THERMISTOR ASSEMBLY), EAD62708424-(Harness,Multi), tested fine