UV MODULE ERROR

Cause

Ultra-Violet dispenser sanitizing led module bad.

Solution

Troubleshooting and inspection must be done to find the root cause of this error code.

LG InstaView: Refresh your dispenser nozzle with UV Nano – YouTube

[LG Refrigerator] – Operation of UVnano & dispenser lights on a Side-by-Side model – YouTube

NOTE:

UV clean function runs automatically for 10 minutes every hour or can be manually activated at any time.

Press and hold the “Self Care” button for 3 seconds to activate it manually.

During operation, the function stops if the Water button is pressed.

It resumes automatically after 1 hour. 

The function runs automatically for 10 minutes every hour without requiring you to press the Self Care button.

DETAILS BELOW:

This is the board for the UV Light

It appears from the models we have been able to see, that the wire colors at the Module PCB remain the same, that is. RD 12Vdc, BK Gnd, SB Sig.

On the other side of the connector the harness changes color going into the door, Light BL/WH, BL/BO, PU/WH.

At the Sub PCB on top of the door (on our model LRYKC2606S) the same wire colors are present on CON 2

With this dispenser design, it will be easier to check voltages at the UV PCB

With the unit in “Self Care” mode we saw the following voltages, 9.38dc on 12V to Gnd, and 2.9dc on Signal to Gnd.