WATER FLOW METER ERROR

Cause

Flow meter located on the pilot valve is defective

Solution

Check wiring and connections to flow meter and   check flow meter resistance and voltages

Cause

No water supplied or very low water pressure

Solution

Check customer for water supplied, water filter clogged or possible failure of water valve.

DETAILS BELOW:

FLOW METER ERROR CODE CHECKS

Some flow meters will be labeled as above chart shows. With the flow meter disconnected you can read from middle “O” to right side “U” to check for 4~30kΩ

Some flow meters will be labeled as above diagram. With the flow meter disconnected you can read from the Ground pin Black to the 5V wire White/Black to check for 4~30kΩ

If you believe the water valve is the issue, then check resistance of the water valves…

120 Volts AC Water Valves will read 360~420Ω

DC VOLTAGE valves need at least 20.4VDC to activate

24VDC Pilot valve 69~73 ohms

24VDC Water/Ice valve 24~26.5 ohms