CONDENSER FAN ERROR
Cause
The Main board has stopped receiving a feedback signal from the Condenser Fan.
Solution
Check The fan for movement, (if fan won’t move without power applied replace fan) or other issues that might stall fan.
Check the fan shroud for mis-alignment.
Test Voltages in Test Mode 1
DETAILS BELOW:
32 Responses
Seguir enviando información LG. Gracias
“Keep sending information LG. Thank you”
Customer used a dolly to move from the back! Bent frame. Was able to straighten out.
#Se # Not a sealed system issues. Customer concern about CF error code. Replaced bad condenser fan test unit works perfectly
Not cooling properly. CF E displayed on the panel. Condenser fan not working. Replace condenser fan. All tested ok. No leaks after test. Customer instruct 24 hrs for going to the correct temperatures.
Dispenser not working, CF error.
Condenser fan jammed up due to crooked fan shroud, part readjusted, tested fine.
Unit not cooling due to condenser fan motor failure
Fan is not running
Condensor fan CF error code is not running
LRMVS3006S/01 condenser fan not running cf error code. Turned into CL error code