Combo HP Digital_COMPRESSOR ERROR 1

COMPRESSOR ERROR 1 Cause Compressor is locked Solution Check the Compressor connections and wire harness. If no defect is found replace the Duct assembly as shown. DETAILS BELOW: TESTING Place in LQC Mode Spin +Soil & Power Advance Advance the test mode to step 17. Watch the fan RPM, (should be approximately 4000). And the […]
Combo HP Digital_DRUM TEMP ERROR (DUCT IN)

DRUM TEMP ERROR (Duct In) Cause Drum Temperature is too high. Solution Dryer fire detection (The system checks the “Duct In” temperature at 10-second intervals during drying; if it increases by more than 17 degrees) you will see the error. DETAILS BELOW: To access the “Duct in” sensor follow these steps Step 1: Remove the […]
Combo HP Digital_FILTER ASSEMBLY ERROR

FILTER ASSEMBLY ERROR Cause The Duct assembly lint filter is not installed, or the switch is bad. Solution The Duct assembly lint filter needs reinstalled or check the filter switch and magnet. DETAILS BELOW: Location of Filter Switch The Filter switch is Normally Closed (NC). Without the filter housing installed if you check across the […]
Combo HP Digital_TEMP SENSOR ERROR 5 (EVA OUT)

TEMP SENSOR ERROR 5 (Eva Out) Cause Temperature is abnormal Solution Check the sensor if its in range or at least is not “open” or “Shorted” If the sensor is good replace the main PCB. If the sensor is not good you will need to replace the entire Duct Assembly. DETAILS BELOW: The “Eva Out” […]
Combo HP Digital_Combo HP Digital_TEMP SENSOR ERROR 4 (EVA IN)

TEMP SENSOR ERROR 4 (Evaporator-In) Cause Temperature is abnormal Solution Check the sensor if its in range or at least is not “open” or “Shorted” If the sensor is good replace the main PCB. If the sensor is not good you will need to replace the entire Duct Assembly. DETAILS BELOW: The “Evaporator-in” sensor location. […]
Combo HP Digital_TEMP SENSOR ERROR 2 COMPRESSOR TEMPERATURE IS ABNORMAL

TEMP SENSOR ERROR 2 COMPRESSOR TEMP IS ABNORMAL Cause Temperature is abnormal Solution Check the sensor if its in range or at least is not “open” or “Shorted” If the sensor is good replace the main PCB. If the sensor is not good you will need to replace the entire Duct Assembly. DETAILS BELOW: The […]
Combo HP Digital_TEMP SENSOR ERROR 3 (DUCT OUT)

TEMP SENSOR ERROR 3 (Duct Out) Cause Temperature is abnormal Solution Check the sensor if its in range or at least is not “open” or “Shorted” If the sensor is good replace the main PCB. If the sensor is not good you will need to replace the entire Duct Assembly. DETAILS BELOW: The location of […]
Combo HP Digital_WATER SUPPLY

WATER SUPPLY Cause Correct water level (24.6 kHz) is not reached within 8 minutes after water is supplied or it does not reach the preset water level within 20 minutes. Water supply faucets are not fully open, or low water pressure. Water inlet hoses are kinked, pinched, or crushed. Solution Make sure that the water […]
Combo HP Digital_TEMP SENSOR ERROR 1 (DUCT IN)

TEMP SENSOR ERROR 1 (Duct In) Cause Temperature is abnormal Solution Check the sensor if its in range or at least is not “open” or “Shorted” If the sensor is good replace the main PCB. If the sensor is not good you will need to replace the entire Duct Assembly. DETAILS BELOW: To access the […]
WAC_Co

Auto Clean Function (Not An Error)