DRY_F1

TEMPERATURE TOO HIGH ERROR Cause The temperature in the drum is too high due to not enough air flow. Solution 1. Remove the lint trap from the dryer. 2. Remove lint and rinse the filter then re-install. 3. Condenser dryers, remove the condenser. Then wash and clean, then re-install. 4. Heat pump dryers have a fixed […]

DRY_EE

DEFECTIVE EEPROM ERROR EEPROM stands for electrically erasable programmable read-only memory To test Enter test mode, At first press of the start button does the unit display the EE error code?  Replace the main board

DRY_NF

WI FI IS NOT CONNECTED TO ROUTER Cause Not an Error Code.  Appliance has not been connected to router and registered. Only shows during test mode Solution The appliance can be connected to wi /fi then resistered using the smart thinQ app 1.Download the LG ThinQ app from the App Store. Download LG ThinQ.  See […]

DRY_NE

MODEM IS ABNORMAL ERROR Cause There is a problem with the customers router and Wi-Fi module communication.  Only shows in test mode Solution Customer need to check or reset their router or wi/fi module is defective and needs to be replaced.

DRY_NU

NFC MODULE ERROR Cause  NFC module open or shorted.  nC or nU is displayed only in the test mode. Solution  Replace NFC module.

DRY_NC

NFC MODULE ERROR Cause  NFC module open or shorted.  nC or nU is displayed only in the test mode. Solution  Replace NFC module.

DRY_F0

FILTER NOT INSERTED ERROR Cause  An “F0” (FO) error code will display and the machine will not start if the lint filter is left out of the machine. Solution Check for lint filter installed and if not then properly install the filter Cause A magnet embedded in the lint filter activates the reed switch mounted […]

DRY_HS

HUMIDITY SENSOR ERROR Cause If dryer is not completely cool, HS error may display when “installation check” or “Flow Sense” test (duct work flow test) is run. Both Installation check and/or Flow Sense test must be run when unit is cold or results will not be accurate. Flow Sense Test is looking for a temperature […]

DRY_E5

STEAM PUMP ERROR Cause When the pump valve is less than 10 in the test mode. E5 error is only displayed in the test mode. Solution Check the connection between harness wire and connector Check for 15 to 20 ohms on the steam pump motor windings Check to see during test mode if Main PCB is […]

DRY_LE2

DRUM MOTOR HAS LOW AMPERAGE ERROROR COMPRESSOR ERROR Special Note: The LE2 Error has different meanings based on if the Dryer is a standard Condensing model or a Heat Pump Model. Troubleshooting for both styles is described in the article below… Heat Pump Dryer Info (Click Here) Standard Condensing: Cause Lint filter clogged Solution If […]