ThinQ UP FEATURE Dishwasher

THINQ UP FEATURE “UP” is not an error code but is a notification that your ThinQ Appliance has a Feature update and needs to be uploaded. If the customer needs assistance, they can call the ThinQ team at 575-424-2555 The above display will rotate the segments a total of six times, as shown, followed by the default status when giving the […]

ThinQ UP FEATURE Front Load

THINQ UP FEATURE “UP” is not an error code but is a notification that your ThinQ Appliance has a Feature update and needs to be uploaded. If the customer needs assistance, they can call the ThinQ team at 575-424-2555 The above display will rotate the segments a total of six times, as shown, followed by the default status when giving the […]

ThinQ UP FEATURE DRYER

THINQ UP FEATURE “UP” is not an error code but is a notification that your ThinQ Appliance has a Feature update and needs to be uploaded. If the customer needs assistance, they can call the ThinQ team at 575-424-2555 The above display will rotate the segments a total of six times, as shown, followed by the default status when giving the […]

ThinQ UP FEATURE TOP LOAD

THINQ UP FEATURE “UP” is not an error code but is a notification that your ThinQ Appliance has a Feature update and needs to be uploaded. If the customer needs assistance, they can call the ThinQ team at 575-424-2555 The above display will rotate the segments a total of six times, as shown, followed by the default status when giving the […]

ThinQ UP FEATURE

THINQ UP FEATURE “UP” is not an error code but is a notification that your ThinQ Appliance has a Feature update and needs to be uploaded. If the customer needs assistance, they can call the ThinQ team at 575-424-2555 The above display will rotate the segments a total of six times, as shown, followed by the default status when giving the […]

DRY_TE7

EVAPORATOR INLET THERMISTOR ERROR CODE Cause Evaporator Inlet Thermistor Open, Short Solution Check Evaporator Inlet Thermistor resistance and compare to the chart. DETAILS BELOW: Check from the main board white 8 pin connector from pin2 black wire to pin3 brown wire to read the resistance of the evaporator inlet thermistor and compare to the temperature […]

DRY_IF

FILTER MISSING ERROR (INSTALL FILTER) Cause  An “IF” (IF) error code will display, and the machine will not start if the lint filter is left out of the machine. A magnet embedded in the lint filter activates the reed switch mounted internally in the plastic housing of the vent duct. Solution Check for lint filter […]