FREEZER FAN ERROR

Cause

The Main board has stopped receiving a feedback signal from the Freezer Fan.

Solution

Check the fan area for heavy ice stopping the fan blade, or other issues that might stall fan.       

(the issue could be a Defrost issue instead of a fan issue).

DETAILS BELOW:

166 Responses

  1. RNN230831082992 found refrigerator with ffe error code. Replaced grill fan assembly and unit is working and cooling properly

  2. RNN230903097499

    Freezer fan bearing going bad, makimg loud noise. No ice restriction. Replacwd freezer evap grill assembly

  3. RNN230907016414

    Doors were reversed incorrectly causing frost and dew formation, caused not to cool in the FF section as well. Both doors readjusted, tested fine.

  4. RNN231010087180 #SW /00 R600a 2.0oz Customer concern about FFE error code on and off bad freezer fan. After doing compressor job on 10/3/23 RNN230929030796. Tie at replaced complete grill with Dan and sensor explained to customer all the service prosses

  5. FF code. Also, replaced comp/dryer per DMS. 165v, .64 amps, -12 psi LS, 45 HS, normal balance.

    RNN231011090896

  6. RNN231017019803. Evaporator fan not running
    Found wobbling shaft on fan motor. Replaced fan motor and grille assembly. Cleared ice from return.

  7. E FF displayed. Freezer fan not working. No ice detected around, fan blade not spinning. Replace grille assembly, fan. All tested ok. RNN231031084748

  8. RNN231028074460

    Not cooling properly, not air movement. Found dead Evap fan. Parts replaced; AEB75144907-(Grille Assembly,Fan), test fine

  9. RNN231030077656
    Not cooling properly, not spinning fast enough, very noisy. 3 dots from left to right. Found defective Evap fan motor. Part replaced; AEB75144906-(Grille Assembly,Fan), tested fine

  10. RNN231030077656
    Not cooling properly, makes a lot of noise. Found defective Evap fan motor. Part replaced;

  11. RNN231106011445
    Found unit with a FF error code technician found damaged freezer fan assembly and also duct assembly. Technician installed new user interface also ice maker and grill fan assembly & multi duct assembly retested unit is working properly as designed #nosealdissue

  12. RNN231109033406
    3 light error code, top freezer model with excess frost build up in freezer and ref duct. Replaced grille assembly after removing excess frost

  13. RNN231004056512
    #SW #Not a sealed system issues. /10 R600a 1.9oz Customer concern about EFF error code. Replaced defective grill assembly freezer fan motor was bad

  14. RNN231117069196
    #SW #Not a sealed system issue. FFE error code bad freezer fan evaporator is all frosted indicating perfect sealed system. Replaces compmeted grill test unit works perfectly

  15. RNN231206061079

    FF E, Unit not cold enough, refrigerator jig used to test,( fan err) found dead freezer fan. Part replace; AEB73764521-(Grille Assembly,Fan), #SW

  16. RNN231213098419

    Freezer is zero, ice working. Fan not blowing, refr temp is 55. Comp 1s 155 v, .48 amps, but not air flow to refr section. Frost pattern normal.

  17. FF error message displayed. Freezer fan faulty. Customer unplugged 2 times and error again. No icde around the blade. Replace grille assembly, fan. All tested ok. No leaks after test. RNN240102074756

Leave a Reply

Your email address will not be published. Required fields are marked *