COMMUNICATION ERROR

Cause

If CO is displayed The Main board and Display have stopped communicating with each other.

 

Solution

Check the wiring at the left-hand hinge connections & the associated voltages.

DETAILS BELOW:

Continuity Test:

  1. Set meter to continuity and check the Rx/Tx lines from the Main PCB to the Left Door Hinge connector, this checks the wiring through the cabinet.
  2. Check continuity on Rx/Tx lines from the Left Door Hinge connector to the Display PCB, this checks the wiring in the door.

 

Note: If there is an open wire in the circuit the greatest chance will be the wiring for either the Rx/Tx in the door is open. It is very rare for a wire in the cabinet to open.

5 Responses

  1. RNN231213096848

    CO error code. All connectors good at boards and under hinge. TS flowchart shows main pcb issue. Main replaced

  2. RNN240105098975

    FF error code
    Not getting airflow to ref section. Temps normal in freezer (0)
    Freezer fan not running during test mode

Leave a Reply

Your email address will not be published. Required fields are marked *