If CO is displayed The Main board and Display have stopped communicating with each other.
Solution
Check the wiring at the left-hand hinge connections & the associated voltages.
DETAILS BELOW:
Continuity Test:
Set meter to continuity and check the Rx/Tx lines from the Main PCB to the Left Door Hinge connector, this checks the wiring through the cabinet.
Check continuity on Rx/Tx lines from the Left Door Hinge connector to the Display PCB, this checks the wiring in the door.
Note: If there is an open wire in the circuit the greatest chance will be the wiring for either the Rx/Tx in the door is open. It is very rare for a wire in the cabinet to open.
10 Responses
CO error code. All connectors good at boards and under hinge. TS flowchart shows main pcb issue. Main replaced
10 Responses
CO error code. All connectors good at boards and under hinge. TS flowchart shows main pcb issue. Main replaced