The pressure sensor frequency has exceeded 213 and is detecting an overflow of water.
DETAILS BELOW:
Use test mode to check water level frequency Is the water level frequency over 21.3kHz? (When adding water does your number decrease on display?) If no: does water flow continuously into tub with unit unplugged? If so, defective inlet valve.
If water is not being continuously supplied with unit unplugged Is voltage being supplied to the inlet valve when power to washer is on, but no wash cycle is selected? If yes: defective main pcb. If no: check for connection between main PCB and pressure switch.
If water level frequency is being read (in test mode):
Inspect for blockages and leaks in air hose between tub and pressure switch. Replace hose if needed.
Check for link accumulation in air chamber. Clean out air chamber.
Recheck for FE error code. If FE still displayed, check pressure switch connection.
Pressure switch will have resistance of 20Ω to 25Ω from the violet to sky blue wire.