Wiring connections for pumps, (6
pin) and for sensors (4 pin) (Detergent WHITE and ORANGE).
Pumps power supply between 11.5 to
13.5 VDC at terminals 5 and 1 (detergent) and 3 and 4 (softener) on 6 pin
connector.
Pumps resistance values
are
about 36 ohms.
Both pumps are powered at step 13
in Test mode, (If no voltage in test mode, from main board replace main board,