STEAM PUMP ERROR

Cause

When the pump valve is less than 10 in the test mode. E5 error is only displayed in the test mode.

Solution

Check the connection between harness wire and connector

Check for 15 to 20 ohms on the steam pump motor windings

Check to see during test mode if Main PCB is supplying 9 to 12V dc to the steam pump

DETAILS BELOW:

Check to see during test mode if Main PCB is supplying 9 to 12V dc to the steam pump.

Check for 15 to 20 ohms on the steam pump motor windings.

NOTE: The Steam Generator is replaced as a complete assembly.