COMPRESSOR ERROR

Cause

Compressor failure

Solution

Check compressor voltage and winding values

May require new compressor or Main PCB

DETAILS BELOW:

The below example is for a heat pump dryer
using an inverter BLDC Compressor 240 VOLTS

Resistance : 2.56 ±0.3Ω (BLUE&RED)

Resistance : 2.56 ±0.3Ω (RED&BLACK)

Resistance : 2.56 ±0.3Ω (BLACK&BLUE

The below example is for a heat pump dryer using a reciprocating compressor 120Vac.

Resistance values are:

Yellow wire to Blue wire  = 1.21 ±7%Ω

Yellow wire to White wire  = 5.04 ±7%Ω

The voltage is 120Vac

 

The below wiring diagram is from model DLHX4072