BLDC Compressor / Main PCB Blink Codes

Definition: FCT0 Trip (Voltage)

Trip Logic: Abnormal IPM sensing voltage.

Reaction: Main PCB will apply power to the compressor after 30 seconds.

Purpose: Main PCB circuit protection.

Most Likely Cause: Main PCB Failure.

Definition: Over Voltage Trip

Trip Logic: Detection of over voltage to the Main PCB DC link (above 450vDC)

Reaction: Compressor is switched off.  Main PCB applies power to the compressor after 4 minutes.

Purpose: Protect the PCB from over voltage output.

Most Likely Cause: Full or partial restriction close to the compressor outlet. Liquid forming in the outlet of the compressor. Internal compressor failure.

Definition: No ConnectionTrip

Trip Logic: Main PCB Detects open circuit to the compressor.

Reaction: Compressor is switched off. Main PCB applies power to the compressor after 4.5 minutes.

Purpose: Protection for the main PCB (Over-Voltage and Over-Current)

Most Likely Cause: Open compressor winding. Open harness between PCB and compressor and or capacitor.

Least Likely Cause: Main PCB

There currently is not a 4-Blink Error for BLDC Compressors. Only Linear Compressors will show a 4-Blink Error On the Main PCB.

Definition: Locked Piston Trip

Trip Logic: Main PCB fails to detect piston movement.

Reaction: Compressor is switched off. Main PCB applies power to the compressor after 6.5 minutes.

Purpose: Main PCB and Sealed System protection.

Most Likely Cause: Seized compressor piston, cylinder damage, internal debris, or high side restriction close to the compressor.

Least Likely Cause: Failed Main PCB.

Definition: Over Current Trip

Trip Logic: Main PCB detects over current condition on the compressor circuit.

Reaction: Compressor is switched off. The Main PCB applies power to the compressor after 6 minutes

Purpose: Main PCB and Sealed System protection

Most Likely Cause: Sealed System – Low side leak, internal compressor issue (piston damage, cylinder damage or internal debris), partial high side restriction close to the compressor, Open winding on BLDC Compressor

Least Likely Cause: Long door openings, high heat load, high ambient temperatures (over 109F), poor air flow through the condenser, installation (to close to the wall), Condenser Fan Failure, or Main PCB Failure (IPM Breakdown)

Definition: IPM Fault Trip

Trip Logic: Main PCB Detects IPM Short

Reaction: Compressor is switched off. The Main PCB applies power to the compressor every  300 seconds. 

Purpose: Main PCB  and Sealed System protection.

Most Likely Cause: Main PCB IPM Failure.

Least Likely Cause: Shorted compressor, compressor harness or possible sealed system problem. Wrong Compressor Installed.

Definition: Main PCB Tx Error Trip

Trip Logic: 12vDC Communication error detected

Reaction: Only LED blinking while compressor is running. (Compressor will continue the last order from main micom.)

Purpose: Main PCB protection from a shorted 12vDC component.

Most Likely Cause: Shorted or failed DC component. Examples : fan motor, flow meter, sub-PCB, ice maker, water tubing heater, shorted harness, ETC

Least Likely Cause: Main PBC

Not A Cause: The compressor will not cause an 8x blink code

Definition: Overload Trip (Overpower)

Trip Logic: Main PCB Detected an overload condition.

Reaction: Compressor is switched off. Main PCB applies power to the compressor after 360 seconds.

Purpose: Main PCB protection from overload

Most Likely Cause: High temperature, environmental condition, condenser fan error, poor air flow, dirty condenser, internal compressor problem, IPM failure

Least Likely Cause: Main PCB

There currently is not a 10-Blink Error for BLDC Compressors. Only Linear Compressors will show a 10-Blink Error On the Main PCB.

Constantly ON or Constantly Flashing LED Codes...

Constantly ON LED...

Definition: Main PCB Defect

Trip Logic: Main PCB has failed

Reaction: Compressor is switched off.

Purpose: Main PCB protection from overload

Most Likely Cause: Main PCB

Constantly Flashing LED...

Definition:12vDC Short

Trip Logic: Short on 12vDC Circuit is Detected.

Reaction: All power to the unit is turned off.

Purpose: Main PCB circuit protection.

Most Likely Cause: Short on the 12vDC circuit, evaporator fan, condenser fan, ice room fan, ice maker, etc