TV Power Supply Blinking Errors
POWER SUPPLY BLINK CODES
WAC_41

DISCHARGE PIPE SENSOR ERROR Cause Discharge Pipe Sensor Open / Shorted Solution Test the discharge pipe sensor to make sure it is not reading open or shorted. Cause Wiring Issue to Discharge Pipe Sensor. Solution Inspect the wiring harness for pinched or broken wires. Also check wiring connectors at Main PCB and sensor for issues.
kimchi_RF

Top-Right Compartment / Middle Compartment Fan Motor Malfunction Cause If rF is displayed The Main Board has stopped receiving a feedback signal from the Top-right compartment 0r Middle Compartment fan motor. (Depends on Specific Model). Solution Check The connections at the Fan motor and the Main PCB. (Please see your specific units Schematic for correct […]
kimchi_E4

Right Drawer Sensor Malfunction (Bottom Right Compartment) Cause If E4 is displayed the Right Drawer Sensor is disconnected or shorted. Solution Check the connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) Refrigerator
kimchi_E3

Left Drawer Sensor Malfunction (Bottom Left Compartment) Cause If E3 is displayed the Left Drawer Sensor is disconnected or shorted. Solution Check the connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) Refrigerator
kimchi_E2

Right Compartment Sensor Malfunction Cause If E2 is displayed the Right Compartment Sensor is disconnected or shorted. Solution Check the connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) Refrigerator
kimchi_E1

Left Compartment Sensor Malfunction Cause If E1 is displayed the left compartment sensor is disconnected or shorted. Solution Check The connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) Refrigerator
kimchi_LF

(Top) Left Compartment / Bottom Fan Motor Malfunction Cause If LF is displayed The Main board has stopped receiving a feedback signal from the Left compartment fan motor. Solution Check The connections at the Fan motor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW:
kimchi_F2

(Top) Right Compartment Sensor Malfunction Cause If F2 is displayed The Main PCB has stopped receiving a feedback signal from the Upper / Right compartment sensor. Solution Check the connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW:
kimchi_F1

(Top) Left Compartment Sensor Malfunction Cause If F1 is displayed The Main PCB has stopped receiving a feedback signal from the Upper / Left compartment sensor. Solution Check the connections at the sensor and the Main PCB. (Please see your specific units Schematic for correct wire colors and pin numbers.) DETAILS BELOW: