Cause
When the pump valve is less than 10 in the test mode. E5 error is only displayed in the test mode.
Solution
Check the connection between harness wire and connector
Check for 15 to 20 ohms on the steam pump motor windings
Check to see during test mode if Main PCB is supplying 9 to 12V dc to the steam pump
Check to see during test mode if Main PCB is supplying 9 to 12V dc to the steam pump.
Check for 15 to 20 ohms on the steam pump motor windings.
NOTE: The Steam Generator is replaced as a complete assembly.