EZ DISPENSER (SOFTENER) ERROR

Cause

The amount of Softener in the reservoir did not decrease. The unit senses an open circuit in the Softener pump.

Solution

Check connections at pump, and Main board.

DETAILS BELOW:

Wiring connections for pumps, (6 pin) and for sensors (4 pin) (Detergent WHITE and ORANGE).

Pumps power supply between 11.5 to 13.5 VDC at terminals 5 and 1 (detergent) and 3 and 4 (softener) on 6 pin connector.

Pumps resistance values are about 36 ohms.

Both pumps are powered at step 13 in Test mode, (If no voltage in test mode, from main board replace main board, if you have voltage at pump replace pump.)